How To Configure Advanced Features In Built-In CDR Solution¶
Change Log Level¶
It is possible to change the logging level of the CDR solution. Default log level is Debug.
To do so, go to the following path on the CDR server: C:\Program Files\Votiro\SDS Web Service\Config
, and modify logs.xml file.
All log settings are defined in this file (e.g., LogLevel, MaxFileSize, NumberOfBackups etc.) and can be updated.
These settings are valid for each sanitization node. Same goes for the API and SNMC logs.
After updating the settings in the logs.xml, the SNMC and API services must be restarted on the CDR server.
Download Big Files¶
In the Shield built-in CDR solution there is a known limitation for file size. Maximum size allowed for sanitization is 2.1 GB.
In order to allow larger files, follow these steps:
- Go to
C:\Program Files\Votiro\SDS Web Service
- Edit
SdsApiService.exe.config
file: increase the maxReceivedMessageSize underWEBHttpBinding_ISdsWebService
andWEBSecureHttpBinding_ISdsWebService
to the desired size (in bytes) - Go to
C:\Program Files\Votiro\SDS Web Service\config
- Edit
machine.xml
file: underSystemSettings
add MaxInProcessSizeInBytes=”5368709120” with the same size you entered in step 2. - Restart both services –
Votiro.Sanitization.API
andVotiro.SNMC
.
Update User Displayed Message¶
For archived folders, when the included files are blocked (by the CDR process), they are replaced with a pdf document to inform the user that the item has been blocked. It is possible to change the message displayed to the user by updating the dictionary template located on the CDR server.
The dictionary templates are located in C:\Program files\Votiro\SDS Web Service\Templates\Dictionaries
After updating the dictionary templates, the SNMC and API services must be restarted on the CDR server.